Validation test between finite element analysis and laboratory experiment.

von Mises stress (MPa)Error (%)
FEM (present study)Experimental test [37]

Plate with one longitudinal stiffener27.226.563.61
Plate with two longitudinal stiffeners169.4179.65.67

Displacement (mm)Error (%)
FEM (present study)Experimental test [37]

Plate with one longitudinal stiffener0.1380.1352.22
Plate with two longitudinal stiffeners0.8540.9136.46

Strain (—)Error (%)
FEM (present study)Experimental test [37]

Plate with one longitudinal stiffener0.0001360.000134.61
Plate with two longitudinal stiffeners0.0008540.000905.11