Research Article

Preimpact Fall Detection for Elderly Based on Fractional Domain

Table 7

The fall prealarming accuracy and lead time of part of the test set.

MotionAccuracy of data set 1Lead time of data set 1 ()Accuracy of data set 2Lead time of data set 2 ()

Walking-fainting0.889-0.880367-4330.917-0.856567-500
Walking-slipping0.845-0.743333-2330.880-0.789433-367
Walking-tripping0.753-0.688433-3670.838-0.668433-668
Jogging-fainting0.664-0.930467-3330.651-0.846467-433
Jogging-slipping0.515-0.874267-2670.571-0.920200-267
Jogging-tripping0.617-0.807200-2670.631-0.719267-433

Note. The prediction result of KNN algorithm is on the left side, and the prediction result of integrated learning algorithm is on the right side.