Research Article

Study on the Semiactive Control and Optimal Layout of a Hydropower House Based on Magnetorheological Dampers

Table 8

The response of the generator floor characteristic points after the optimal layout.

ResponseNo controlPassive-onImproved simple bang-bang

The maximum vertical velocity response point (vertical velocity; mm/s)Before optimization3.2942.729 (17.15%)2.257 (31.48%)
Optimized2.493 (24.32%)2.086 (36.67%)
Optimization effect7.16%5.19%
The maximum vertical acceleration response point (vertical acceleration; m/s2)Before optimization0.6810.617 (9.40%)0.550 (19.24%)
Optimized0.601 (11.75%)0.520 (23.64%)
Optimization effect2.35%4.41%