Research Article

T-Shaped Control Plate Effect on Flow past a Square Cylinder at Low Reynolds Numbers

Table 4

Influence of Lu for Re = 250, L/D = 5, β = 13, and Ld = 39D.

LuCDmeanStCDrmsCLrms

5−0.2698 (5.5%)0.1148 (5.7%)0.0359 (4.7%)0.3192 (5.1%)
10−0.28460.10830.03420.3028
15−0.2798 (1.7%)0.1066 (1.6%)0.0337 (1.5%)0.2987 (1.4%)
20−0.2803 (1.5%)0.1066 (1.6%)0.0338 (1.2%)0.2998 (1.0%)