Research Article

Hardware-in-the-Loop Implementation and Performance Evaluation of Three-Phase Hybrid Shunt Active Power Filter for Power Quality Improvement

Table 2

Comparative analysis of the control techniques in this research work for HSAHPF.

Control techniquesParameters
THD (%)Stability time (sec)Sampling time (sec)Power factor

Pq0 implemented in Simulink3.120.065e − 080.998
Pq0 implemented in Arduino3.440.065e − 060.982
Id − Iq implemented in Simulink2.010.035e − 081
Id − Iq implemented in Arduino2.380.045e − 060.993