Residual deformation under seismic wave.

Residual deformationCast in place (mm)Assembly, 16 mm (mm)Assembly, 18 mm (mm)Assembly, 20 mm (mm)

El Centro seismic wave3140.90.4
Tafts seismic wave2000.4
Artificial seismic wave2000