Research Article

Thermal Analysis of Axial-Flux Permanent Magnet Motors for Vehicles Based on Fast Two-Way Magneto-Thermal Coupling

Table 5

Comparison of transient temperature rise of winding and permanent magnet.

Time (s)Stator windingPermanent magnets
Thermal network methodMeasurementsError rate (%)Thermal network methodMeasurementsError rate (%)

28027.226.14.2135.334.62.02
33858.656.73.3536.435.33.12
458118.3114.33.5039.338.13.15
467140.7135.24.0740.939.43.81
150056.053.05.6680.978.53.06