Research Article

An Optima Combination Method of Three-Frequency Real-Time Cycle Slip Detection for Non-Normal Ionospheric Variation Data

Table 2

Detection results of artificial cycle slips combinations.

True epochSampling rate (s)Estimated epochDetection values Comparison result class
Without With

601600.999 (G09), 1.008 (G27)1.000 (G09), 1.001 (G27)Consistent
125121.072 (G09), 1.025 (G27)1.149 (G09), 0.989 (G27)Consistent
61561.166 (G09), 1.258 (G27)1.011 (G09), 0.998 (G27)Consistent
42041.180 (G09), 1.322 (G27)0.998 (G09), 0.996 (G27)Consistent
3253−0.722 (G09), −0.476 (G27)−0.982 (G09), 1.030 (G27)Consistent
4254−0.476 (G09)−0.982 (G09)Missing
2550.533 (G27)0.002 (G27)Misjudgment
2560.549 (G27)0.006 (G27)Misjudgment
33031.327 (G09), 1.568 (G27)1.012 (G09), 0.976 (G27)Consistent
4304−0.326 (G27)−1.001 (G27)Missing
3050.544 (G09), 0.613 (G27)−0.000 (G09), 0.001 (G27)Misjudgment
30160.554 (G09)0.019 (G09)Misjudgment
30310.563 (G09)0.014 (G09)Misjudgment