NumberParameter (°C)Parameter Parameter (m2/h)Parameter [kj/(m2·h·°C)]Parameter [kj/(m2·h·°C)]

120.02.280.108653.9493.9
220.23.090.095546.7812.2
320.41.830.082439.61130.6
420.62.640.069432.4200.0
520.83.460.056325.3518.4
621.02.190.043318.2836.7
721.23.010.113511.01155.1
821.41.740.100455.9224.5
921.62.560.087348.8542.9
1021.83.380.074341.6861.2
1122.02.110.061234.51179.6
1222.22.930.048227.3249.0
1322.41.660.118420.2567.3
1422.72.480.105313.1885.7
1522.93.300.092258.01204.1
1623.12.030.079250.8273.5
1723.32.850.066143.7591.8
1823.51.580.053136.5910.2
1923.72.400.040029.41228.6
2023.93.210.110222.2298.0
2124.11.950.097115.1616.3
2224.32.770.084160.0934.7
2324.51.500.071052.91253.1
2424.72.320.058045.7322.4
2524.93.130.044938.6640.8
2625.11.870.115131.4959.2
2725.32.680.102024.31277.6
2825.53.500.089017.1346.9
2925.72.230.075910.0665.3
3025.93.050.062954.9983.7
3126.11.790.049847.81302.0
3226.32.600.120040.6371.4
3326.53.420.106933.5689.8
3426.72.150.093926.31008.2
3526.92.970.080819.21326.5
3627.11.700.067812.0395.9
3727.32.520.054756.9714.3
3827.63.340.041649.81032.7
3927.82.070.111842.71351.0
4028.02.890.098835.5420.4
4128.21.620.085728.4738.8
4228.42.440.072721.21057.1
4328.63.260.059614.11375.5
4428.81.990.046559.0444.9
4529.02.810.116751.8763.3
4629.21.540.103744.71081.6
4729.42.360.090637.61400.0
4829.63.170.077630.4469.4
4929.81.910.064523.3787.8
5030.02.720.051416.11106.1