Research Article

Parameter Estimation of Solar PV Using Ali Baba and Forty Thieves Optimization Technique

Table 10

Comparison of actual and experimental values for the Photowatt-PWP201 module.

S.noImIeIAE (current)VPePmIAE (power)RE

11.03151.0297280.00177160.12480.128510.1287310.0002210.0017204
21.031.0276610.00233891.80931.8593471.8635790.0042320.002276
31.0261.0257250.00027553.35113.4373053.4382290.0009230.0002686
41.0221.0238330.00183334.76224.8756994.8669680.008731−0.0017906
51.0181.0218140.00381366.05386.1858556.1627680.023087−0.0037322
61.01551.0193230.00382297.23647.3762287.3485640.027664−0.0037505
71.0141.0157330.00173328.31898.4497838.4353650.014418−0.0017064
81.011.0099782.15 × 10−059.30979.4025969.4027970.0002012.13 × 10−05
91.00351.0004090.003090610.216310.2204810.252060.0315750.0030894
100.9880.9847430.003257311.044910.8763810.912360.0359770.0033078
110.9630.9601890.002811311.801811.3319511.365130.0331790.0029279
120.92550.9238740.001626412.492911.5418611.562180.0203180.0017604
130.87250.8735660.001066413.123111.463911.44990.013995−0.0012208
140.80750.8082030.000702713.698311.07111.061380.009626−0.0008695
150.72650.728550.002049914.222110.3615110.332360.029154−0.0028137
160.63450.6366330.002133214.69959.358199.3268330.031357−0.0033508
170.53450.5354270.000927215.13468.1034768.0894440.014033−0.0017317
180.42750.4281980.000698315.53116.650396.6395450.010845−0.0016307
190.31850.3178490.000651315.89295.0515375.0618890.0103510.0020492
200.20850.2070070.001492916.22293.3582553.3824750.0242190.0072119
210.1010.0976450.003354716.52411.6135011.6689340.0554330.0343558
22−0.008−0.008590.000590716.7987−0.14431−0.134390.009922−0.0687572
23−0.111−0.110972.62 × 10−0517.0499−1.89209−1.892540.0004470.0002361
24−0.209−0.208610.000391217.2793−3.60461−3.611370.006760.0018753
25−0.303−0.300930.002072417.4885−5.26277−5.299020.0362430.0068867
IAE (current)0.0425533IAE (power)0.45291