Research Article

Dynamic Response and Fatigue-Life Analysis of High-Speed Railway Tunnel Base with Defects

Table 3

Physical and mechanical parameters of joint of coarse aggregate in different positions.

Position of coarse aggregate junctionDensity (kN/m3)Elastic modulus (MPa)Poisson’s ratioCohesion (MPa)Internal friction angle (°)

Primary lining19.7015.800.181.0422.00
Secondary lining20.4016.100.181.3223.00
Filled layer16.9014.300.181.0420.90
Concrete foundation21.8016.600.181.2023.40
Track slab23.8017.200.181.5224.50