Research Article
Mathematical Model for Energy and Exergy-Based Simulation of Triangular Solar Energy Extractor for Air Heating Applications
Table 2
Typical value of design and operating conditions.
| Design and operating parameters | Value |
| Length (L) and width (W) of the duct | 1.5 m | Thickness (δi) of insulation | 0.06 m | Glass transparent cover thickness (tg) | 0.004 m | Thermal conductivity value of insulation (ki) | 0.04 W/mK | Thermal conductivity value of glass cover (kg) | 0.75 W/mK | Radiation of intensity (I) | 1000 W/m2 | Atmospheric temperature (Ta) | 300 K | Temperature rise parameter (ΔT/I) | 0.002–0.03 K·m2/W | Reynolds number (Re) | 2000–35000 | Relative roughness height (e/Dh) | 0.021–0.043 | Relative roughness pitch (P/e) | 4–16 | Inclination angle of arc (α) | 30–75° |
|
|