Research Article

Mathematical Model for Energy and Exergy-Based Simulation of Triangular Solar Energy Extractor for Air Heating Applications

Table 2

Typical value of design and operating conditions.

Design and operating parametersValue

Length (L) and width (W) of the duct1.5 m
Thickness (δi) of insulation0.06 m
Glass transparent cover thickness (tg)0.004 m
Thermal conductivity value of insulation (ki)0.04 W/mK
Thermal conductivity value of glass cover (kg)0.75 W/mK
Radiation of intensity (I)1000 W/m2
Atmospheric temperature (Ta)300 K
Temperature rise parameter (ΔT/I)0.002–0.03 K·m2/W
Reynolds number (Re)2000–35000
Relative roughness height (e/Dh)0.021–0.043
Relative roughness pitch (P/e)4–16
Inclination angle of arc (α)30–75°