Research Article
Application of FIFD-OMGD-1.5D Teager Energy to Extract Microfault Features of Rolling Bearing
Table 3
Fault feature frequency extracted by different methods and average relative error with different SNRs.
| Fault feature Frequency (Hz) | SNR | Algorithm | −3 | −5 | −7 | −9 | −11 | −13 | −15 | Average relative error |
| True | 100 | 100 | 100 | 100 | 100 | 100 | 100 | | FIFD-OMGD (based on protrugram algorithm) | 99.8 | 99.8 | 99.8 | 100.2 | 100.2 | 99.8 | 100.2 | 0.000200 | FIFD-OMGD (based on fast kurtogram algorithm) | 101 | 98.98 | 98.98 | 101 | 98.98 | 98.98 | 98.98 | 0.010143 | CEEMDAN-OMGD | 101 | 101 | 102.2 | 101 | 101.6 | 98.98 | 102 | 0.014029 | FIFD-MCKD | 100.1 | 100.1 | 101 | 98.6 | 107.3 | 111.8 | 89.4 | 0.046142 |
|
|