Research Article

Multithreaded Multiswarm Model for Intelligent Economic Prosumer Load Dispatch for Battery Supported DC Microgrid

Table 8

Compassion of ABC and PSO for a full load range.

TimeLoad (W)PSOABCBest
HG (W)MG (W)Time (m/s)Total (W)HG (W)MG (W)Time (m/s)Total (W)

1106.726.9653113.6812.33088.2512.33ABC
22014.779.2152223.9818.073.1974.6621.26ABC
32520.2510.7231430.9724.424.1175.0328.53ABC
44026.6714.5630741.2341.052.5380.643.58PSO
55039.914.2231454.1245.238.7286.453.95ABC
66037.2930.2631067.5552.519.7190.762.22ABC
77550.2526.2531476.564.9518.8886.883.83PSO
89057.7141.3731799.0857.3436.9582.394.29ABC
910069.4538.76310108.2164.1245.6187109.73PSO

Note.HG: home grid; MG: main grid.