Research Article
The Application of the Design of the Experiment to Investigate the Stability of Special Equipment
Table 3
The true values of the influencing factors correspond to the range of change’s upper and lower limits.
| Input factors | The value of factors at the center of the plan | Upper limit (“+”) | Lower limit (“-”) |
| Z1, MPa | 30 | 33 | 27 | Z2 | 1.055 | 1.065 | 1.045 | Z3, times of caliber | 4.00 | 4.40 | 3.60 | Z4, MJ/kg | 1.00 | 1.10 | 0.90 | Z5, MPa.s | 0.81 | 0.891 | 0.729 | Z6 | 0.2210 | 0.2486 | 0.1934 | Z7, dm3/kg | 1.00 | 1.10 | 0.90 | Z8, kg/m3 | 1600 | 1760 | 1440 | Z9, kg/dm3 | 0.554 | 0.6149 | 0.4931 |
|
|