Research Article

Seismic Response Analysis of Isolated and Nonisolated Continuous Girder Bridges under Multidimensional Near-Field Ground Motions

Table 6

Failure of isolation bearings under different types of ground motions.

Fling-step ground motions
BearingTCU054TCU065TCU068TCU072TCU076TCU082Yarimca

Bearing011010011
Bearing11110111
Bearing21111111
Bearing31111111
Bearing41111111
Bearing020010011

Forward-directional ground motions
BearingDuzceJFPABuildingLexington DamSCSESOVMFFTCU101TCU102

Bearing010100001
Bearing11111111
Bearing21111111
Bearing31111111
Bearing41111111
Bearing020100001

Far-field ground motions
BearingAbbarAnzaTuleBakerFireBigBearCalexicoLaCCNthTaft

Bearing010000000
Bearing10000000
Bearing20000000
Bearing30000000
Bearing40000000
Bearing020000000