Research Article

Experimental and Numerical Simulations Predictions Comparison of Power and Efficiency in Hydraulic Turbine

Table 3

Comparison between numerical and experimental data.

[m3/s]Power measured [MW]Power simulated [MW]Efficiency measured [%]Efficiency simulated [%]

89.6731.6531.9585.1085.25
76.1429.0330.0291.1691.82
60.9922.6322.8887.8488.39
52.9019.0219.9384.9286.00
35.6810.1410.2365.8966.09