Table of Contents Author Guidelines Submit a Manuscript
Modelling and Simulation in Engineering
Volume 2013, Article ID 964910, 13 pages
http://dx.doi.org/10.1155/2013/964910
Research Article

Multiple Dissipative Devices for Blast-Resisting Cable-Supported Glazing Façades

Department of Engineering and Architecture, University of Trieste, Piazzale Europa 1, 34127 Trieste, Italy

Received 27 May 2013; Accepted 16 September 2013

Academic Editor: Laurent Mevel

Copyright © 2013 Claudio Amadio and Chiara Bedon. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. J. Wei, M. S. Shetty, and L. R. Dharani, “Stress characteristics of a laminated architectural glazing subjected to blast loading,” Computers and Structures, vol. 84, no. 10-11, pp. 699–707, 2006. View at Publisher · View at Google Scholar · View at Scopus
  2. S. Zhao, L. R. Dharani, and X. Liang, “Analysis of damage in laminated architectural glazing subjected to blast loading,” Advances in Structural Engineering, vol. 11, no. 1, pp. 129–134, 2008. View at Publisher · View at Google Scholar · View at Scopus
  3. M. V. Seica, M. Krynski, M. Walker, and J. A. Packer, “Analysis of dynamic response of architectural glazing subject to blast loading,” Journal of Architectural Engineering, vol. 17, no. 2, pp. 59–74, 2011. View at Publisher · View at Google Scholar · View at Scopus
  4. J. Wei, M. S. Shetty, and L. R. Dharani, “Failure analysis of architectural glazing subjected to blast loading,” Engineering Failure Analysis, vol. 13, no. 7, pp. 1029–1043, 2006. View at Publisher · View at Google Scholar · View at Scopus
  5. J. Wei and L. R. Dharani, “Fracture mechanics of laminated glass subjected to blast loading,” Theoretical and Applied Fracture Mechanics, vol. 44, no. 2, pp. 157–167, 2005. View at Publisher · View at Google Scholar · View at Scopus
  6. J. Wei and L. R. Dharani, “Response of laminated architectural glazing subjected to blast loading,” International Journal of Impact Engineering, vol. 32, no. 12, pp. 2032–2047, 2006. View at Publisher · View at Google Scholar · View at Scopus
  7. M. Larcher, G. Solomos, F. Casadei, and N. Gebbeken, “Experimental and numerical investigations of laminated glass subjected to blast loading,” International Journal of Impact Engineering, vol. 39, no. 1, pp. 42–50, 2012. View at Publisher · View at Google Scholar · View at Scopus
  8. P. Hooper, H. Arora, and J. P. Dear, “Blast and impact resistance of laminated glass structures,” in Proceedings of the IMPLAST Symposium on Plasticity and Impact Mechanics, Providence, RI, USA, 2010.
  9. D. C. Weggel and B. J. Zapata, “Laminated glass curtain walls and laminated glass lites subjected to low-level blast loading,” Journal of Structural Engineering, vol. 134, no. 3, pp. 466–477, 2008. View at Publisher · View at Google Scholar · View at Scopus
  10. D. C. Weggel, B. J. Zapata, and M. J. Kiefer, “Properties and dynamic behavior of glass curtain walls with split screw spline mullions,” Journal of Structural Engineering, vol. 133, no. 10, pp. 1415–1425, 2007. View at Publisher · View at Google Scholar · View at Scopus
  11. C. Amadio and C. Bedon, “Blast analysis of laminated glass curtain walls equipped by viscoelastic dissipative devices,” Buildings, vol. 2, pp. 359–383, 2012. View at Google Scholar
  12. X. Zhang, H. Hao, and G. Ma, “Parametric study of laminated glass window response to blast loads,” Engineering Structures, vol. 56, pp. 1707–1717, 2013. View at Google Scholar
  13. M. Teich, P. Warnstedt, and N. Gebbeken, “The influence of negative phase loading on cable net facade response,” Journal of Architectural Engineering, vol. 18, no. 4, pp. 276–284, 2012. View at Publisher · View at Google Scholar
  14. F. Wellershoff, “Design methods and structural components of blast enhanced façades,” in Proceedings of the Challenging Glass 3-International Conference on Architectural and Structural Applications of Glass, F. Bos, C. Louter, R. Nijsse, and F. Veer, Eds., pp. 28–29, IOS Press, Delft, The Netherlands, June 2012.
  15. F. Wellershoff, G. Lori, M. Zobec, and K. Osterland, “Structural design of blast enhanced cable net facades,” in Proceedings of the COST Action TU0905 Mid-Term Conference on Structural Glass, J. Belis, C. Louter, and D. Mocibob, Eds., pp. 121–131, 2013.
  16. C. Amadio and C. Bedon, “Viscoelastic spider connectors for the mitigation of cable-supported façades subjected to air blast loading,” Engineering Structures, vol. 42, pp. 190–200, 2012. View at Google Scholar
  17. C. Amadio and C. Bedon, “Elastoplastic dissipative devices for the mitigation of blast resisting cable-supported glazing façades,” Engineering Structures, vol. 39, pp. 103–115, 2012. View at Publisher · View at Google Scholar · View at Scopus
  18. GSA-TSO1-2003, “Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings,” U.S. General Service Administration, 2003.
  19. ABAQUS, v. 6.10, Computer software, Simulia, Dassault Systemes, Providence, RI, USA.
  20. M. Larcher and G. Solomos, “Laminated glass loaded by air blast waves—experiments and numerical simulations,” Tech. Rep. JRC57559, Joint Research Centre, Pubsy, 2010. View at Google Scholar
  21. R.-Q. Feng, L.-L. Zhang, Y. Wu, and S.-Z. Shen, “Dynamic performance of cable net facades,” Journal of Constructional Steel Research, vol. 65, no. 12, pp. 2217–2227, 2009. View at Publisher · View at Google Scholar · View at Scopus
  22. M. L. Lai, P. Lu, D. A. Lunsford, K. C. Chang, and K. Kasai, “Viscoelastic damper: a damper with linear or nonlinear material?” in Proceedings of 11th World Conference on Earthquake Engineering, Acapulco, Mexico, 1996.
  23. T. T. Song and G. F. Dargush, Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Sons, 1997.