Research Article
Instantaneous Power Theory with Fourier and Optimal Predictive Controller Design for Shunt Active Power Filter
Table 2
The error of instantaneous active power for harmonic component calculation.
| Frequency (Hz) | | | | error (%) | PQ | PQF |
| 300 | 173.3885 | 171.3400 | 173.3175 | 1.18 | 0.04 | 600 | 59.5549 | 59.3269 | 59.4681 | 0.38 | 0.15 | 900 | 27.7095 | 27.6630 | 27.6932 | 0.17 | 0.06 | 1200 | 13.9776 | 14.0036 | 14.0208 | 0.19 | 0.31 |
| | 1.92 | 0.56 |
|
|