Research Article

Energy Analysis of Commercial Buildings Using Artificial Neural Network

Table 1

Building specification.

TypeNameMaterial

WallExterior wall100 mm sandcrete plaster
150 mm sandcrete block
100 mm sandcrete plaster
WindowSide windows3 mm thick glass
13 mm window air fill
3 mm thick glass
PartitionMedium partitionsG01a 19 mm gypsum board
F04 wall air space resistance
G01a 19 mm gypsum board
WallHeavy/medium partitions10 mm sandcrete plaster
100 mm brick
10 mm sandcrete plaster
RoofMedium roof/ceiling100 mm heavyweight concrete tiles
Ceiling air space resistance
Ceiling tiles
Roofing sheet
Roof deck
FloorMedium floorFloor tiles
100 mm heavyweight concrete