Bidirectional Effect of Repeated Exposure to Extremely Low-Frequency Electromagnetic Field (50 Hz) of 1 and 7 mT on Oxidative/Antioxidative Status in Rat’s Brain: The Prediction for the Vulnerability to Diseases
Table 1
Results of statistical analysis of the oxidative markers concentrations in the prefrontal cortex.
Dependent variable
Effect
a
CP basal level
Intensity of the electromagnetic field (mT)
2
22.133
<0.001
Number of exposures
2
16.681
<0.001
4
9.851
<0.001
Error
68
b
8-epi PGF2α basal level
Intensity of the electromagnetic field (mT)
2
15.231
<0.001
Number of exposures ()
2
0.191
0.827
4
2.343
0.063
Error
73
c
Open field-induced CP level
Intensity of the electromagnetic field (mT)
2
190.737
<0.001
Number of exposures ()
2
19.793
<0.001
4
12.051
<0.001
Error
71
d
Open field-induced 8-epi PGF2α level
Intensity of the electromagnetic field (mT)
2
13.921
<0.001
Number of exposures ()
2
0.657
0.522
4
7.753
<0.001
Error
66
F: GLM; statistically significant value: indicated in italic; CP: protein carbonyl groups.