Research Article

An Objective Study of Anatomic Shifts in Intracranial Hypotension Using Four Anatomic Planes

Table 1

Average measurements of recorded distances, comparing normal with grades of IH.

VariableNormalAll IHGrade 1Grade 2Grade 3

Distance from mammillary body tip to incisura line3.39 −0.98 2.26 0 −3.80

Distance from the diaphragm sella to the optic chiasm2.07 3.53 1.8

Angle of the optic chiasm7.42 (3.93)−4.95 (10.2)−0.68 (7.63)−1.19 (5.41)−9.71

Height of the interpeduncular cistern at the plane of the cecum12.76 10.39

Mammillopontine distance7.07 4.47 5.32 4.6 3.79

Ratio of interpeduncular cistern0.56 0.40 0.46 0.40 0.36

Distance from iter to tuberculum-venous confluence line0.20 −2.51 −0.62 −4.67

Distance from splenium of the corpus callosum to the incisura line0.99 −0.73 0.52 0.06 −2.01

Distance from caudal pole of tonsils to plane of the foramen magnum1.98 −2.20 −1.71

Distance from obex to plane of foramen magnum8.36 5.30 4.98 5.27 5.52

All measurements without are in mm with standard deviations provided in (). demarks measurements in degrees.