Current Approaches for Image Fusion of Histological Data with Computed Tomography and Magnetic Resonance Imaging
Table 2
Quantitative comparison of the stated similarities and resolution for the image-to-image strategies taken from the literature discussed.
| Author | Matching criteria | Stated similarity | 3D resolution (per pixel) | Relative accuracy |
| Xiao et al. [10] | Intensity | L1-norm | 270 µm | — | Nagara et al. [49] | Feature | Dice index, Jaccard index, recall, and NCC | Dataset 1 : 49 µm, dataset 2 : 52 µm | — | Groen et al. [51] | Intensity | 600 µm (best value used) | 18 µm | 0.03 | Katsamenis et al. [64] | Landmark | — | 8.84 µm | — | Seise et al. [52] | Intensity/landmark | 500 µm (worst value used) | 400 µm | 0.8 | Albers et al. [5] | Intensity | Displacement index | 2.33 µm | — | Magee et al. [58] | Intensity | 200 µm | 50 µm | 0.25 |
|
|