Research Article

Nonlinear Biomechanical Characteristics of Deep Deformation of Native RBC Membranes in Normal State and under Modifier Action

Table 1

Young’s modulus for RBC membranes of healthy donors.

Donor12345678

(kN/m2), sample mean , and standard deviation24.9 ± 6.925.1 ± 3.627 ± 6.925.2 ± 4.925.7 ± 4.327.1 ± 6.325.8 ± 627.1 ± 5.6