Potentiodynamic polarization parameters for pure nickel and Ni-AlN coatings with 3, 6, and 9 g/L AlN particles using 3.5 wt.% NaCl aqueous solution at the scan rate of 0.167 mV s−1.

Sample, V, mV decade−1, mV decade−1 (μA cm−2)

Ni0.0890.0982.57
Ni-AlN-3 g/L0.1050.0912.15
Ni-AlN-6 g/L0.2790.0451.95
Ni-AlN-9 g/L0.3430.0361.29