Research Article

The Effects of Sand Particles on the Synergy of Cavitation Erosion-Corrosion of MIG Welding Stainless Steel Coating in Saline Water

Table 3

Comparative summary of electrochemical corrosion results for the PHMSS coating in 3.5 wt.% NaCl solution with and without 3 wt.% sand particles.

Conditions (μA/cm2) (mV vs. SCE)

Sand-free (static)3.026-273.6
Sand-containing (static)1.326-153.1
Sand-free (CE)0.582-167.2
Sand-containing (CE)3.538-251.8