Research Article

Evaluation of the Bond Strengths between Dental Porcelain and Cobalt-Chromium Metal Frameworks Manufactured with Different Techniques after the Thermal Aging Process

Table 6

Descriptive statistics and -test result of porcelain binding strengths (MPa) between groups with and without thermal aging application.

Mean (SD)MinMax value

CastingThermal cycle1542.02 (6.26)31.9855.030.6679
CastingControl1542.81 (3.11)36.0446.13
CAD/CAM (milling)Thermal cycle1551.99 (7.64)37.0165.580.5447
CAD/CAM (milling)Control1553.72 (7.74)40.5768.11
EOS (laser sintering)Thermal cycle1542.36 (1.23)40.0644.220.0608
EOS (laser sintering)Control1543.94 (2.19)40.2746.92
Concept (laser sintering)Thermal cycle1543.91 (2.63)39.2348.560.2109
Concept (laser sintering)Control1545.01 (2.05)41.0349.05

SD: standard deviation; Min: minimum; Max: maximum.