Research Article

Establishment and Verification of Multiaxis Fatigue Life Prediction Model

Table 4

Stress and strain states of the specimen at the point of danger.

NumberDangerous node numberStress (MPa)Strain (%)Shear strain (%)Damage amount

1-1175336.5770.56120.15541.913
1-2175342.6790.57140.15821.983
1-3175354.9360.59180.16392.127
1-4175367.1750.61220.16952.2764
1-5175379.4140.63260.17522.40
1-6175397.7730.66320.18362.674
2-1175415.3770.35710.81562.455
2-2175374.9790.32650.733620.1
2-318791355.910.3570.81652.86
2-418791319.1890.3060.73362.376