Research Article
Can Dental Office Lighting Intensity Conditions Influence the Accuracy of Intraoral Scanning?
Table 1
Description of data organization, light intensity, and evaluated conditions.
| Group # | Lux | Simulated conditions | Scan # |
| Group 1–N.C. | 400 | Neon ambient light on a cloudy day | N.C.1 | N.C.2 | N.C.3 | N.C.4 | N.C.5 | Group 2–L.N. | 1 000 | Neon ambient light on a sunny day | L.N.1 | L.N.2 | L.N.3 | L.N.4 | L.N.5 | Group 3–U.J. | 3 300 | Chair light at half intensity | U.J.1 | U.J.2 | U.J.3 | U.J.4 | U.J.5 | Group 4–U.J.N. | 3 800 | Chair light at half intensity and neon ambient light | U.J.N.1 | U.J.N.2 | U.J.N.3 | U.J.N.4 | U.J.N.5 | Group 5–U.F. | 10 000 | Chair light at full intensity | U.F.1 | U.F.2 | U.F.3 | U.F.4 | U.F.5 | Group 6–U.F.N. | 11 000 | Chair light at full intensity and neon ambient light | U.F.N.1 | U.F.N.2 | U.F.N.3 | U.F.N.4 | U.F.N.5 |
|
|