High Content Analysis of Human Pluripotent Stem Cell Derived Hepatocytes Reveals Drug Induced Steatosis and Phospholipidosis

Table 5

Comparison of assay imprecision for each parameter measured in hiPSC derived hepatocytes (hiPS-HEP) and HepG2.

Assay parameterVariation between wells in a plateVariation between plates in a batchVariation between batches
hiPS-HEPHepG2hiPS-HEPHepG2hiPS-HEPHepG2
CVCVCV%CV%CV%CV%

CC (fixed)6.8 ± 4.88.9 ± 2.613.04.126.722.6
CC (live)15.3 ± 12.318.9 ± 17.325.825.535.335.0
NC
 MI2.4 ± 1.31.0 ± 0.66.022.34.112.9
 Area2.3 ± 1.12.2 ± 0.96.46.75.56.9
ST
 MI6.3 ± 2.75.0 ± 4.69.95.721.48.6
 Area3.9 ± 3.13.5 ± 4.51.110.76.69.5
PH
 MI3.2 ± 1.51.8 ± 1.47.94.58.14.0
 Area2.4 ± 1.010.2 ± 10.518.137.013.32.8
MMP
 MI4.7 ± 6.23.4 ± 2.712.322.16.822.4
ROS
 MI0.9 ± 0.844.1 ± 2.84.07.35.85.2
PMP
 MI4.8 ± 3.022.6 ± 2.03.914.70.623.0

Imprecisions of cell-to-cell within a well, well-to-well within a plate, plate-to-plate within a batch, and batch-to-batch are compared for all parameters measured. For calculating well-to-well variance, a mean, SD, and CV% were calculated for every control well () and an average CV% of all the eight plates was reported for well-to-well variation. The well-to-well mean values for each parameter within a batch () were then averaged and its CV% was calculated. The average CV% from the four batches was used to show plate-to-plate variation. For batch-to-batch variance, the mean values from each plate were averaged and its CV% was reported ().