Research Article
Simultaneous Quantification of Dexpanthenol and Resorcinol from Hair Care Formulation Using Liquid Chromatography: Method Development and Validation
Table 3
System suitability and method validation data for the simultaneous quantification of DP and RC.
| Parameters | Resorcinol | Dexpanthenol |
| System suitability | | | Retention time (min) | 7.19 | 3.19 | Capacity factor | 1.08 | 1.32 | Peak resolution | 15.41 | — | Tailing factor | 0.97 | 0.56 | Theoretical plates () | | | Sensitivity | | | LOD (µg·mL−1) | 2.19 | 0.62 | LOQ (µg·mL−1) | 6.64 | 1.89 | Precision | | | Intraday | | | Mean content (mg/100 mL) () ± % RSD | 50.41 ± 0.19 | 49.77 ± 0.20 | Interday | | | Mean content (mg/100 mL) (day 1/day 2/day 3) () | 50.40/50.38/50.39 | 49.76/49.78/49.65 | (% RSD) (day 1/day 2/day 3) () | 0.20/0.19/0.21 | 0.11/0.19/0.15 | Specificity | | | Peak purity angle | 0.129 | 0.217 | Peak purity threshold | 0.337 | 0.411 |
|
|
With respect to DP.
|