Research Article
Side-Channel Leakage Detection with One-Way Analysis of Variance
Table 4
Detection results of the 8-bit MCU implementation.
| Detection method | 1,000 traces | 3,000 traces | 5,000 traces |
| LD_ANOVA | D | 38 points | 4 points | 39 points | | 18/36.73% | 0/0% | 0/0% | | 29/59.18 | 45/91.84% | 10/20.41% | | 20/41.82% | 4/8.16% | 39/79.59% |
| TVLA | D | 1 point | 1 point | 28 points | | 0/0% | 0/0% | 0/0% | | 48/97.96% | 48/97.96% | 21/42.86% | | 1/2.04% | 1/2.04% | 28/57.14% |
| LD_CS | D | 0 points | 0 points | 0 points | | 0/0% | 0/0% | 0/0% | | 49/100% | 49/100% | 49/100% | | 0/0% | 0/0% | 0/0% |
|
|