Research Article
Side-Channel Leakage Detection with One-Way Analysis of Variance
Table 5
Monochannel and multichannel leakage detection results for the FPGA implementation.
| Leakage | 10,000 traces | 20,000 traces | 30,000 traces |
| Power traces | D | 1 point | 21 points | 68 points | | 0/0% | 4/2.72% | 7/4.76% | | 146/99.32% | 130/88.44% | 86/58.50% | | 1/0.68% | 17/11.56% | 61/41.50% |
| EM traces | D | 0 points | 19 points | 52 points | | 0/0% | 0/0% | 2/1.64% | | 122/100% | 103/84.43% | 72/59.02% | | 0/0% | 19/15.57% | 50/40.98% |
| Fused traces | D | 4 points | 168 points | 355 points | | 0/0% | 8/2.35% | 14/4.11% | | 337/98.83% | 181/53.08% | 0/0% | | 4/1.17% | 160/46.92% | 341/100% |
|
|