Area overhead of Berger [
26], SEDC, and m-out-of-2m [
24] code checkers.
| Data Bit | Berger Code | SEDC | m-out-of-2m | Code storage Area | 1’s counter Area | TRC Area | Total Area | Code storage Area | Checker Area | AND-OR Network | Total Area | Code Storage Area | Checker Area | AND-OR Network | Total Area |
| 2 | 24 | 22 | 4 | 50 | 24 | 26 | 0 | 50 | 24 | 36 | 0 | 50 |
| 3 | 24 | 80 | 8 | 112 | 24 | 50 | 0 | 74 | 36 | 152 | 0 | 188 |
| 4 | 36 | 180 | 12 | 228 | 36 | 58 | 6 | 100 | 48 | 240 | 10 | 298 |
| 5 | 36 | 178 | 16 | 230 | 48 | 76 | 6 | 130 | 60 | 300 | 14 | 374 |
| 7 | 36 | 396 | 24 | 456 | 60 | 108 | 8 | 176 | 84 | 420 | 18 | 522 |
| 8 | 48 | 550 | 28 | 626 | 72 | 126 | 8 | 206 | 96 | 480 | 20 | 596 |
| 15 | 48 | 1106 | 56 | 1210 | 120 | 250 | 14 | 384 | 180 | 900 | 38 | 1118 |
| 16 | 60 | 1308 | 60 | 1428 | 132 | 258 | 16 | 406 | 192 | 960 | 40 | 1192 |
| 30 | 60 | 2586 | 116 | 2762 | 240 | 500 | 26 | 766 | 360 | 1800 | 76 | 2236 |
| 32 | 72 | 3048 | 120 | 3240 | 264 | 526 | 28 | 818 | 384 | 1920 | 80 | 2384 |
|
|