Research Article

ICS Software Trust Measurement Method Based on Dynamic Length Trust Chain

Table 3

Algorithm validation results.

Test caseUse integrity measurementDo not use integrity measurement

Use correct start_openplc.sh fileSuccessfulSuccessful
Modify one of the security-sensitive filesUnsuccessfulSuccessful
Modify the file bool_true.png that does not affect the applicationSuccessfulSuccessful
Update libmodbus.o with security measuresSuccessfulSuccessful
Infect files with a virus bootkit [39ā€“41]UnsuccessfulSuccessful