Three-Dimensional Reconstruction Algorithm of Computed Tomography Imaging for Surgical Treatment and Rapid Rehabilitation Nursing of Renal Cell Carcinoma
Table 1
Quality assessment of 3D reconstructed CT image.
Score
Trunk and branches of renal artery/renal vein
Edge of blood vessel
Artifacts caused by breathing motion
Other
1
The trunk and primary branches could be displayed clearly
Fuzzy
Yes or no
—
2
The trunk, primary, and secondary branches could be displayed clearly
Smooth
No
The secondary branches <4
3
The trunk, primary, secondary, and tertiary branches could be displayed clearly
Smooth
No
The secondary branches <5
4
The trunk, primary, secondary, and tertiary branches could be displayed clearly
Smooth
No
The secondary branches ≥5
5
The trunk, primary, secondary, tertiary, and quaternary branches could be displayed clearly