Research Article
Biomechanical Evaluation of a Mandibular Spanning Plate Technique Compared to Standard Plating Techniques to Treat Mandibular Symphyseal Fractures
Table 3
Statistical analysis summary.
| Test | Between groups | Statistical significance | value |
| Peak load | Control versus 2PP | Yes | 0.004 | Peak load | Control versus SP1 | No | 0.04 | Peak load | Control versus LS | No | 0.09 | Peak load | 2PP versus SP1 | Yes | 0.009 | Peak load | 2PP versus LS | Yes | 0.009 | Peak load | SP1 versus LS | No | 0.92 | Stiffness | Control versus 2PP | Yes | 0.004 | Stiffness | Control versus SP1 | No | 0.01 | Stiffness | Control versus LS | No | 0.01 | Stiffness | 2PP versus SP1 | Yes | 0.009 | Stiffness | 2PP versus LS | Yes | 0.009 | Stiffness | SP1 versus LS | No | 0.92 |
|
|
considered statistically significant.
|