Research Article

Development Considerations of AREVA NP Inc.'s Realistic LBLOCA Analysis Methodology

Table 3

Summary of S-RELAP5 assessment matrix.

Test facility Tests used Key phenomena of interestReferences

THTF heat transfer35Heat transfer[2528]
THTF level swell3Void distribution[29]
GE level swell1Void distribution[30]
FRIGG-227Void distribution[31]
Bennet tube2Heat transfer[32]
Flecht and flech-seaset9Heat transfer, nodalization, axial power distribution,[33, 34]
scalability, entrainment
PDTF/SMART4Spacer effects[35]
Marviken9Break flow[36]
W/EPRI 1/3 scale9Cold leg condensation, interfacial heat transfer[37]
MiniLoop CCFL3Upper tie plate CCFL[38]
Multidimensional flow3Core flow distribution[39]
UPTF14ECCS bypass, steam binding, CCFL, scalability,[4045]
nodalization
CCTF4Steam binding, nodalization, scalability[4350]
SCTF6Nodalization[51]
ACHILLES1Accumulator nitrogen discharge[52]
LOFT4Overall code performance, nodalization, scalability[5357]
Semiscale2Blowdown heat transfer, nodalization, scalability,[5860]
compensating errors