Parameters which are regarded relevant with respect to the behaviour of the fuel cladding temperature [21].

ParameterRange of parameter distributionMean Standard deviations Probability distribution
MinMax

Initial conditions

(pressure in DS) [Pa] 6.79 066.93 066.86 063.43 04Normal
(coolant flow rate) [m3/h] 68607140700070Normal
(feedwater temperature) [K] 458.52467.78463.152.32Normal
(steam for in-house needs) [m3/h] 227.7232.32301.15Normal
(reactor thermal power) [W] 2.81 092.99 092.90 094.5 07Normal

Modelling parameters

(water packing) 0 (on)1 (off)1 (off)Discrete
(stratification) 0 (on)1 (off)0 (on)Discrete
(PV term) 0 (on)1 (off)0 (off)Discrete
(CCFL) 0 (on)1 (off)0 (off)Discrete
(thermal front tracking) 0 (on)1 (off)0 (off)Discrete
(mixture level tracking) 0 (on)1 (off)1 (on)Discrete
(scram initiation time) 5.36.36.00.25Normal