Research Article
SBWR Model for Steady-State
and Transient Analysis
Table 10
Sequence of events of closure of main steam isolation valves.
| Elapsed
time (sec.) | Event |
| 0.0 | Reactor under steady-state
condition rate at full power. | 1.0 | Closure of all main
steam isolation valves. | 2.0 | Maximum power peak is reached (120% of rated). | 2.0 | The peak of pressure
is maximum, and the SRVs opening to relief pressure. | | Reactor lever decreases until the emergency
core cooling system actuation. | | Core flow tend to stabilize at new equilibrium
conditions
(natural circulation).
|
|
|