Results obtained by the FLUENT calculations for the dry and wet EFFE tests [15].

Thermal power (kW)Total evaporation rate (g/s)
Test no.Exp.Calc. ( 𝑉 i n = 0  m/s)Calc. ( 𝑉 i n = π‘ˆ i n )Exp.Calc. ( 𝑉 i n = 0  m/s)Calc. ( 𝑉 i n = π‘ˆ i n )

DryDTI0.350.240.32β€”β€”β€”
DT21.170.831.14β€”β€”β€”
DT31.591.191.72β€”β€”β€”

WetWTI2.822.383.081.190.921.20
WT29.608.5611.783.713.334.58
WT315.3412.8618.465.725.007.18

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.