Review Article

Experiments and Modelling Techniques for Heat and Mass Transfer in Light Water Reactors

Table 2

Results obtained by the FLUENT calculations for the dry and wet EFFE tests [15].

Thermal power (kW)Total evaporation rate (g/s)
Test no.Exp.Calc. ( 𝑉 i n = 0  m/s)Calc. ( 𝑉 i n = 𝑈 i n )Exp.Calc. ( 𝑉 i n = 0  m/s)Calc. ( 𝑉 i n = 𝑈 i n )

DryDTI0.350.240.32
DT21.170.831.14
DT31.591.191.72

WetWTI2.822.383.081.190.921.20
WT29.608.5611.783.713.334.58
WT315.3412.8618.465.725.007.18