Research Article

CATHARE Multi-1D Modeling of Coolant Mixing in VVER-1000 for RIA Analysis

Table 2

Final state.

ParameterPlant dataCathare 12 sectorsCathare16 sectorsCathare 24 sectorsUncertainty

Core power, MW286286286286± 60
Pressure above the core, MPa15.59315.58415.58515.585± 0.3
Cold leg no. 1 coolant temp, K555.35555.35 (BC)555.35 (BC)555.35 (BC)± 1.5
Cold leg no. 2 coolant temp, K543.05543.05 (BC)543.05 (BC)543.05 (BC)± 1.5
Cold leg no. 3 coolant temp, K542.15542.15 (BC)542.15 (BC)542.15 (BC)± 1.5
Cold leg no. 4 coolant temp, K542.35542.35 (BC)542.35 (BC)542.35 (BC)± 1.5
Mass flow rate 1, kg/s45664569.84567.44567.5± 200
Mass flow rate 2, kg/s46764677.04676.24676.2± 200
Mass flow rate 3, kg/s46694668.24668.24668.2± 200
Mass flow rate 4, kg/s48194818.24818.24818.2± 200
Reactor mass flow rate, kg/s1873018733.218729.918730± 800
Hot leg no. 1 coolant temp, K554.85554.49554.64555.24± 1.5
Hot leg no. 2 coolant temp, K548.15548.19548.55547.54± 1.5
Hot leg no. 3 coolant temp, K545.75545.54545.53545.48± 1.5
Hot leg no. 4 coolant temp, K546.45546.92546.44546.89± 1.5
Reactor pressure drop, MPa0.4190.4100.4110.411± 0.043