Research Article

Numerical Investigation of Startup Instabilities in Parallel-Channel Natural Circulation Boiling Systems

Table 2

Model-to-prototype scaling ratios [8].

ParameterModel-to-Prototype Ratio

Elevations1/4
Power1/2702.6
Number of fuel rods1/663
Linear heating rate2/1
Core hydraulic diameter1/1
Cross sectional area1/1351.3
Feed flow1/2702.6
Length of links1/4
Number of risers/feeders1/51
Number of downcomers1/4