Research Article

A Procedure to Address the Fuel Rod Failures during LB-LOCA Transient in Atucha-2 NPP

Table 4

Main outcomes from the analysis: zones 2, 3, and 6.

ParameterAverage zone 2Average zone 3Average zone 6Max

T cladding [°C]779.8855.8850.5988.4
T Fuel cl [°C]1315.61652.21681.92054.9
Enthalpy [cal/g]74.488.689.9106.5
Gap P [MPa]6.57.37.38.5
FGR [%]0.010.080.010.84
Gap width [μm]63.661.462.069.0
Cladding outer radius [mm]6.496.496.496.54
ECR [%]0.330.340.320.41
Ox Thick. [μm]2.372.482.363.03