Research Article
The Best Estimate Plus Uncertainty Challenge in the Current Licensing Process of Present Reactors
Table 2
Excerpt from the list of PIE for Atucha II Chapter 15 of FSAR.
| No | Transient | Section FSAR | Adopted evaluation model | Class of accident |
| Increase in heat removal by the secondary system | | 15.1 | | |
| 2 | FW system malfunctions that result in an increase in FW Flow (Stuck Open FW Control Valve) | 15.1.2 | CSA | AOO |
| Spectrum of steam system piping failures inside and outside of containment (MSLB) | | 15.1.5 | — | |
| 5 | Leak of MS line inside the containment | 15.1.5.1 | CSA/RCA/CBA | DBA | 9 | Inadvertent closing of the moderator cooler bypass CV | 15.1.7 | CSA | AOO | 36 | Uncontrolled CR withdrawal at the particular Power level that yields the most severe results | 15.4.2 | CSA | AOO | 41 | Spectrum of rod ejection accidents | 15.4.7 | CSA | DBA |
| Spectrum of SGTR | | 15.6.3 | — |
| 46 | Single SG tube rupture (“Bordihn”: SG Tube Failure) | 15.6.3.1 | CSA | DBA | 56 | 0.1A LOCA cold with sump swell operation | 15.6.5.1.2.4 | QA | DBA |
| Large break LOCA | | 15.6.5.1.3 | — |
| 57 | 2A LOCA cold (DEGB. Different Break Sizes and Positions are investigated) | 15.6.5.1.3.1 | CSA/RCA/CBA | SBDBA | 72 | Leakage on the refueling machine and auxiliary equipment | 15.8.2 | RCA | DBA |
| Anticipated transients without scram (ATWS) | | 15.9 | | |
| 74 | Mechanical failure of the control rods in case of emergency power mode | 15.9.1 | CSA | SBDBA |
|
|