Analysis of Subchannel and Rod Bundle PSBT Experiments with CATHARE 3
Table 1
Distribution of deviations: “calculated minus measured voidfraction” in the different series of single subchannel PSBT tests.
Test number
Average
Standard dev.
Series 1: standard central subchannel
43
4.8%
Series 2: central subchannel close to a thimble
43
5.3%
Series 3: lateral subchannel
20
6.0%
Series 4: corner subchannel
20
3.2%
All series
126
5.0%
We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.