Chronology of the main events in Test 5-2 [
14].
| Event | Exp. (s) | TRACE (s) |
| Break valve opened | 0 | 0 | Scram signal | 95 | 65 | SI signal | 145 | 112 | Primary coolant pumps stopped | 349 | 319 | full opening of SG relief valves | 756 | 696 | AFW starts | 756 | 696 | Initiation of Acc system | ā1320 | 1293 | Full opening of SG safety valves | ā2420 | 2586 | End of test | 13376 | 12000 |
|
|