Chronology of the main events in Test 5-2 [14].

Event Exp. (s) TRACE (s)

Break valve opened 0 0
Scram signal 95 65
SI signal 145 112
Primary coolant pumps stopped 349 319
full opening of SG relief valves 756 696
AFW starts 756 696
Initiation of Acc systemā‰ˆ1320 1293
Full opening of SG safety valvesā‰ˆ2420 2586