Chronology of the main events in Test 1 [10].

EventExp.TRACE

PZR isolation−60 s−60 s
Onset of break0 s0 s
Scram signal1 s4 s
Turbine trip1 s4 s
Primary coolant pumps stopped4 s4 s
Main FW isolated8 s4 s
Start of decay heat20 s22 s
Actuation of ACC154 s155 s
PCT increases164 s163 s
Maximum PCT182 s185 s
Start of LPSI504 s349 s
End of test1533 s500 s