Table of Contents Author Guidelines Submit a Manuscript
Science and Technology of Nuclear Installations
Volume 2012, Article ID 173637, 19 pages
http://dx.doi.org/10.1155/2012/173637
Research Article

SPES3 Facility RELAP5 Sensitivity Analyses on the Containment System for Design Review

1SIET S.p.A., UdP, Via Nino Bixio 27/c, 29121 Piacenza, Italy
2ENEA, UTFISSM, Via Martiri di Monte Sole 4, 40129 Bologna, Italy
3FER, University of Zagreb, Unska 3, 10000 Zagreb, Croatia
4Research and Technology Unit, Westinghouse Electric Company LLC, Cranberry Township, PA 16066, USA

Received 11 March 2011; Accepted 27 July 2011

Academic Editor: Alessandro Del Nevo

Copyright © 2012 Andrea Achilli et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. M. D. Carelli, L. E. Conway, L. Oriani et al., “The design and safety features of the IRIS reactor,” Nuclear Engineering and Design, vol. 230, no. 1–3, pp. 151–167, 2004. View at Publisher · View at Google Scholar · View at Scopus
  2. M. D. Carelli, B. Petrović, L. E. Conway et al., “IRIS design overview and status update,” in Proceedings of the 13th International Conference on Nuclear Engineering (ICONE13-50442 '05), Beijing, China, May 2005.
  3. B. Petrović, M. D. Carelli, and N. Cavlina, “IRIS—international reactor innovative and secure: progress in development, licensing and deployment activities,” in Proceedings of the 6th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids, Dubrovnik, Croatia, May 2006.
  4. M. D. Carelli, B. Petrović, M. Dzodzo et al., “SPES-3 experimental facility design for IRIS reactor integral testing,” in Proceedings of the European Nuclear Conference (ENC '07), Brussels, Belgium, September 2007.
  5. M. Carelli, L. Conway, M. Dzodzo et al., “The SPES3 experimental facility design for the IRIS Reactor simulation,” Science and Technology of Nuclear Installations, vol. 2009, Article ID 579430, 12 pages, 2009. View at Publisher · View at Google Scholar
  6. R. Ferri, A. Achilli, C. Congiu et al., “SPES3 facility and IRIS reactor numerical simulations for the SPES3 final design,” in Proceedings of the European Nuclear Conference (ENC '10), Barcelona, Spain, May June 2010.
  7. T. K. Larson, F. J. Moody, G. E. Wilson et al., “Iris small break loca phenomena identification and ranking table (PIRT),” Nuclear Engineering and Design, vol. 237, no. 6, pp. 618–626, 2007. View at Publisher · View at Google Scholar · View at Scopus
  8. IAEA-TECDOC 1536, “Status of small reactor designs without on-site refuelling (IAEA '07),” 2007.
  9. R. Ferri and C. Congiu, SPES3-IRIS facility nodalization for RELAP5 Mod.3.3 code and steady state qualification. SIET 01 423 RT 08 Rev.0, ENEA FPN-P9LU-017, 2009.
  10. R. Ferri and C. Congiu, SPES3-IRIS facility RELAP5 base case transient analyses for design support. SIET 01 489 RT 09 Rev.0., ENEA FPN-P9LU-035, 2009.
  11. R. Ferri and C. Congiu, SPES3-IRIS facility RELAP5 sensitivity analyses of the Lower Break transient for design support. SIET 01 499 RT 09 Rev.0., FPN- P9LU-040, 2009.
  12. R. Ferri, SPES3-IRIS facility RELAP5 sensitivity analyses on the containment system for design review. SIET 01 526 RT 09 Rev.0., ENEA NNFISS-LP2-017, 2010.
  13. R. Ferri and P. Meloni, Approach for a correct simulation of the SPES3-IRIS Emergency Heat Removal System with the RELAP5/MOD3 Code. SIET 01 745 RT 11 Rev.0. Piacenza, Italy, 2011.
  14. RELAP5 code manual. NUREG/CR-5535/Rev.1 Idaho National Engineering Laboratory (USA), 2001.