Research Article

Severe Accident Simulation of the Laguna Verde Nuclear Power Plant

Table 1

Main sequence of events in a LOCA without cooling effects.

Time (seconds) Event

0.0 The reactor operates to power uprate conditions (2027 MWt).
30.0Loss of external power, loss of coolant in a recirculation loop, closing of the turbine control valves, and trip of the reactor and recirculation pumps.
34.3Low level in the reactor vessel (L2), before high pressure occurs in the drywell. The emergency core cooling systems (HPCS* and RCIC*) are active without injecting. Starts closing insolation valves (MSIV*).
37.4Low-low level (L1) is reached.
40.0Level in the BAF*.
200.0Level below the core support plate.
324.0Hydrogen generation starts.
370.0Maximum temperature at the core surface of 1073 K.
458.0Core damage stage starts with release of fission products.
Maximum Temperature at the core surface of 1185 K.
936.0Control rod damage starts
Maximum temperature at control rod of 2136 K.
1800.0Core damage de 19%.
3600.0Core damage of 78%.

*HPCS: high pressure core spray system; RCIC: reactor core isolation cooling; MISV: main steam insolation valves; BAF: bottom of active fuel.